600W Power Adapter Series
Brand: Klinsun
Global wide-voltage AC input (90-264V)
High efficiency: conversion efficiency 91% max
Low loss: 0.21W max
PC plastic enclosed housing
Indicator light showing status
Global certifications: CB/UL/FCC/GS/CE/UKCA/SAA/PSE/KC
3-year warranty, lifetime maintenance
| Output | Model | FY0508000 | FY0908000 | FY1208000 | FY1507000 | FY1906000 | FY2405000 | FY2904000 | FY3603200 | FY4802500 | FY5502000 | |
| DC Voltage | 5V | 9V | 12V | 15V | 19V | 24V | 29V | 36V | 48V | 55V | Adjustable per customer request | |
| Rated Current | 8A | 8A | 8A | 7A | 6A | 5A | 4A | 3.2A | 2.5A | 2A | Adjustable per customer request | |
| Rated Power | 40W | 72W | 96W | 105W | 114W | 120W | 116W | 115.2W | 120W | 110W | ||
| Current-limiting Protection | 9.6A Max | 9.6A Max | 9.6A Max | 8.4A Max | 7.2A Max | 6A Max | 4.8A Max | 3.9A Max | 3A Max | 2.4A Max | Adjustable per customer request | |
| Output Ripple | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 190mVp-p | 240mVp-p | 290mVp-p | 360mVp-p | 480mVp-p | 550mVp-p | ||
| Voltage Accuracy | ± 10% | ± 5% | ± 5% | ± 5% | ± 5% | ± 5% | ± 3% | ± 2% | ± 2% | ± 1% | ||
| Input | Conversion Efficiency | 85%Min | 87%Min | 88%Min | 88%Min | 88%Min | 89%Min | 89%Min | 89%Min | 90%Min | 91%Min | |
| Standby Power | 0.21W | 0.21W | 0.21W | 0.21W | 0.21W | 0.21W | 0.21W | 0.21W | 0.21W | 0.21W | ||
| Voltage Range | 90-264V | |||||||||||
| Frequency Range | 50~60Hz | |||||||||||
| Input Current | 1.5A Max | |||||||||||
| Power Factor | PFC ≧ 0.9 | |||||||||||
| Inrush Current | 80A Max | |||||||||||
| Protection | Short-circuit Protection | Hiccup mode, auto-recovery after fault removal | ||||||||||
| Over-voltage Protection | Voltage-control circuit failure; output voltage does not exceed rated voltage by 3-5% | |||||||||||
| Safety & EMC | Certification Standard | UL62368/IEC62368 | ||||||||||
| EMC | Class B :EN 55032:2015+A11 EN IEC 61000-3-2:2019 EN 61000-3-3:2013+A1 EN 55035:2017+A11 FCC Part 15 Subpart B:2020 | Applied for on customer request | ||||||||||
| Certifications Obtained | ETL/FCC/GS/CE/UKCA/SAA/PSE/CCC/KC | |||||||||||
| Insulation Resistance | 500VDC 10MΩMin | |||||||||||
| Hi-pot Test | 5mA 3000VAC 60S / Safety grounding 5mA 1500VAC 60S | |||||||||||
| Environment | Operating Temperature | Standard: -29 ~ +45°C; Custom: -40 ~ +55°C | ||||||||||
| Operating Humidity | 10 ~ 90% RH, non-condensing | |||||||||||
| Storage Temperature | -40 ~ +85° | |||||||||||
| Storage Humidity | 20 ~ 85% | |||||||||||
| Other | Dimensions / Weight | 154*60*36MM/0.45KG | ||||||||||
| AC Cable | IEC C8 or C14 connector, 1.2m / country-specific cables configured per customer request | |||||||||||
| DC Cable | Length 1m / 5521, GX aviation connector, XLR connector / adjustable per customer request | |||||||||||
| Service Life | Minimum 30,000 hours at 25°C ambient; 3-year warranty | |||||||||||

Copyright © 2026 Klinsun Power Co.,Ltd. XML LLMS Klinsun Power Klinsun