60W Series LiFePO4 Battery Charger
| Output | Applicable Battery Pack | 2S | 3S | 4S | 5S | 6S | 7S | 8S | 9S | 10S | Notes | |
| Battery Pack Voltage | 6.4V | 9.6V | 12.8V | 16V | 19.2V | 22.4V | 25.6V | 28.8V | 32V | |||
| Max Charging Voltage | 7.3V | 11V | 14.6V | 18.2V | 21.6V | 25.5V | 29.2V | 32.8V | 36.5V | Adjustable per customer request | ||
| Max Charging Current | 30A | 30A | 30A | 25A | 25A | 22A | 19A | 17A | 15.5A | Adjustable per customer request | ||
| Model | FY07330000 | FY11030000 | FY14630000 | FY18025000 | FY21625000 | FY25522000 | FY29219000 | FY32017000 | FY36015500 | |||
| Applicable Battery Pack | 11S | 12S | 13S | 14S | 15S | 16S | 17S | 18S | 19S | 20S | ||
| Battery Pack Voltage | 35.2V | 38.4V | 41.6V | 44.8V | 48V | 51.2V | 54.4V | 57.6V | 60.8V | 64V | ||
| Max Charging Voltage | 40.1V | 43.8V | 47.4V | 51.1V | 54.7V | 58.4V | 62V | 65.7V | 69.3V | 73V | Adjustable per customer request | |
| Max Charging Current | 14A | 13A | 12A | 11A | 10A | 9.5A | 9A | 8.5A | 7.5A | 7.5A | Adjustable per customer request | |
| Model | FY40014000 | FY43813000 | FY47012000 | FY51011000 | FY54610000 | FY58409500 | FY62009000 | FY65708500 | FY69007500 | FY73007500 | ||
| Ripple | ≤ 1% of rated output voltage | |||||||||||
| Voltage Accuracy | ± 0.1-0.3V | |||||||||||
| Current Accuracy | ≤ 5% of rated output current | |||||||||||
| Input | Voltage Range | 90-264V | ||||||||||
| Frequency Range | 50~60Hz | |||||||||||
| Power Factor | PFC ≧ 0.95 | |||||||||||
| Conversion Efficiency | 95.5% Max | |||||||||||
| Input Current | 5A Max | |||||||||||
| Inrush Current | 120A Max | |||||||||||
| Protection | Short-circuit | Short-circuit lockout; recovers after re-plugging AC | ||||||||||
| Over-voltage | Voltage-control circuit failure; output voltage does not exceed rated voltage by 3-5% | |||||||||||
| Over-temperature | Built-in 95°C±5°C thermal switch; reduces output current by 30% after triggering (adjustable for extreme environments) | Can be increased per customer request | ||||||||||
| Reverse-connection Protection | Normal output after correct polarity is detected, or a fuse on the DC cable (blows on reverse polarity; replace to resume normal operation) | Can be increased per customer request | ||||||||||
| Timer Function | Built-in timer; cuts off output when the set time is reached | Can be increased per customer request | ||||||||||
| Full-charge Cut-off | Cuts off output when fully charged | Can be increased per customer request | ||||||||||
| Special Functions | Communication | Supports CAN, 485 and single-wire communication | Can be increased per customer request | |||||||||
| Safety & EMC | Certification Standard | UL1012/IEC60335-2-29/GB4943 | ||||||||||
| EMC | Class B :EN 55014-1:2017+A11 EN IEC 61000-3-2:2019 EN 61000-3-3:2013+A1 EN 55014-2:2015 FCC Part 15 Subpart B:2019 | |||||||||||
| Certifications Obtained | ETL/FCC/GS/CE/UKCA/SAA/PSE/CCC | Applied for on customer request | ||||||||||
| Insulation Resistance | 500VDC 10MΩMin | |||||||||||
| Hi-pot Test | 5mA 3000VAC 60S / Safety grounding 5mA 1500VAC 60S | |||||||||||
| Environment | Operating Temperature | Standard: -29 ~ +45°C; Custom: -40 ~ +55°C | ||||||||||
| Operating Humidity | 10 ~ 90% RH, non-condensing | |||||||||||
| Storage Temperature | -40 ~ +85° | |||||||||||
| Storage Humidity | 20 ~ 85% | |||||||||||
| Other | Dimensions / Weight | 264*135*64MM/2.7KG | ||||||||||
| AC Cable | IEC C14 3-pin plug, 1.2m / country-specific cables configured per customer request | |||||||||||
| DC Cable | Length 1m / GX aviation connector, XLR connector, Anderson, XT30/60/90 series (customer specified) | |||||||||||
| Service Life | Minimum 30,000 hours at 25°C ambient; 3-year warranty | |||||||||||

Copyright © 2026 Klinsun Power Co.,Ltd. XML LLMS Klinsun Power Klinsun

Tel