60W Series NMC Lithium Battery Charger
| Output | Applicable Battery Pack | 1S | 2S | 3S | 4S | 5S | 6S | 7S | 8S | 9S | 10S | Notes |
| Battery Pack Voltage | 3.6V | 7.2V | 10.8V | 14.4V | 18V | 21.6V | 25.2V | 28.8V | 32.4V | 36V | ||
| Max Charging Voltage | 4.2V | 8.4V | 12.6V | 16.8V | 21V | 25.2V | 29.4V | 33.6V | 37.8V | 42V | Adjustable per customer request | |
| Max Charging Current | 8A | 8A | 8A | 7A | 5.5A | 4.5A | 4A | 3.5A | 3A | 3A | Adjustable per customer request | |
| Model | FY0428000 | FY0848000 | FY1268000 | FY1687000 | FY2105500 | FY2524500 | FY2944000 | FY3403500 | FY3803000 | FY4203000 | ||
| Applicable Battery Pack | 11S | 12S | 13S | 14S | 15S | 16S | 17S | 18S | 19S | 20S | ||
| Battery Pack Voltage | 39.6V | 43.2V | 46.8V | 50.4V | 54V | 57.6V | 61.2V | 64.8V | 68.4V | 72V | ||
| Max Charging Voltage | 46.2V | 50.4V | 54.6V | 58.8V | 63V | 67.2V | 71.4V | 75.6V | 79.8V | 84V | Adjustable per customer request | |
| Max Charging Current | 2.5A | 2A | 2A | 2A | 1.8A | 1.6A | 1.5A | 1.5A | 1.5A | 1.3A | Adjustable per customer request | |
| Model | FY4602500 | FY5042000 | FY5462000 | FY5882000 | FY6301800 | FY6721600 | FY7141500 | FY7561500 | FY8001500 | FY8401300 | ||
| Ripple | ≤ 1% of rated output voltage | |||||||||||
| Voltage Accuracy | ± 0.1-0.3V | |||||||||||
| Current Accuracy | ≤ 5% of rated output current | |||||||||||
| Input | Voltage Range | 90-264V | ||||||||||
| Frequency Range | 50~60Hz | |||||||||||
| Power Factor | PFC ≧ 0.9 | |||||||||||
| Conversion Efficiency | 93% Max | |||||||||||
| Input Current | 1.5A Max | |||||||||||
| Inrush Current | 80A Max | |||||||||||
| Protection | Short-circuit | Hiccup mode, auto-recovery after fault removal | ||||||||||
| Over-voltage | Voltage-control circuit failure; output voltage does not exceed rated voltage by 3-5% | |||||||||||
| Over-temperature | Built-in 95°C±5°C thermal switch; reduces output current by 30% after triggering (adjustable for extreme environments) | Can be increased per customer request | ||||||||||
| Reverse-connection Protection | Normal output after correct polarity is detected, or a fuse on the DC cable (blows on reverse polarity; replace to resume normal operation) | Can be increased per customer request | ||||||||||
| Timer Function | Built-in timer; cuts off output when the set time is reached | Can be increased per customer request | ||||||||||
| Full-charge Cut-off | Cuts off output when fully charged | Can be increased per customer request | ||||||||||
| Special Functions | Communication | Supports CAN, 485 and single-wire communication | Can be increased per customer request | |||||||||
| Safety & EMC | Certification Standard | UL1012/IEC60335-2-29/GB4943 | ||||||||||
| EMC | Class B :EN 55014-1:2017+A11 EN IEC 61000-3-2:2019 EN 61000-3-3:2013+A1 EN 55014-2:2015 FCC Part 15 Subpart B:2019 | |||||||||||
| Certifications Obtained | ETL/FCC/GS/CE/UKCA/SAA/PSE/CCC | Applied for on customer request | ||||||||||
| Insulation Resistance | 500VDC 10MΩMin | |||||||||||
| Hi-pot Test | 5mA 3000VAC 60S / Safety grounding 5mA 1500VAC 60S | |||||||||||
| Environment | Operating Temperature | Standard: -29 ~ +45°C; Custom: -40 ~ +55°C | ||||||||||
| Operating Humidity | 10 ~ 90% RH, non-condensing | |||||||||||
| Storage Temperature | -40 ~ +85° | |||||||||||
| Storage Humidity | 20 ~ 85% | |||||||||||
| Other | Dimensions / Weight | 154*60*36MM/0.5KG | ||||||||||
| AC Cable | IEC C8 or C14 connector, 1.2m / country-specific cables configured per customer request | |||||||||||
| DC Cable | Length 1m / 5521, GX aviation connector, XLR connector, Anderson, XT30/60/90 series (customer specified) | |||||||||||
| Service Life | Minimum 30,000 hours at 25°C ambient; 3-year warranty | |||||||||||

Copyright © 2026 Klinsun Power Co.,Ltd. XML LLMS Klinsun Power Klinsun